A white WallMaster control box labeled

WSC 104 – AOV Control Unit

Logo of WindowMaster

Description

WindowMaster WSC 104 smoke control AOV panel (4 Amp) for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation.

Get a quote

In stock, next day delivery

Additional details

  • Control for 24V DC Window Actuators (4 Amp max)
  • 1-Zone
  • Input options for - Manual Call Points, Smoke Sensor, Fire Alarm
  • Comfort Inputs for - Rocker Switch, Thermostat, Wind & Rain Sensor
  • Supplied with batteries
  • Certified and tested in accordance to EN 12101-10

Motor Load

4 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1

WSK 501 – Manual Call Point

WindowMaster WSK 501 manual call point (Breakglass) for use with compatible Smoke Control Panels. Upon a signal from the Manual Call Point (MCP) the AOV or OV Smoke Vent will open releasing the smoke detected in that area.

WSK 503 – Manual Call Point

Windowmaster WSK 503 manual call point (break glass) for use with compatible smoke control panels. Upon a signal from the manual call point (MCP) the AOV or OV smoke vent will open releasing the smoke detected in that area.

SSR-D – Smoke Sensor

SSR-D optical Smoke Sensor for use with our range of smoke control AOV panels. Upon a signal from the SSR-D smoke sensor the AOV Control Panel will send an open signal to the AOV Actuator.

WLA 331 – Rain Sensor

WindowMaster WLA 331 rain sensor (24v) for automatic operation of 24VDC actuators via compatible control panels.

TS2 – Room Thermostat

TS2 room thermostat to automatically operate 24V DC actuators based on room temperature via compatible control units.

S50 – Rocker Switch

S50 rocker switch for the operation of 230V AC Actuators or 24V DC Actuators (via 24V DC controllers)

RRTKEY – Key Switch

RRTKEY Key Switch for operation of 230V AC window actuators. 3 positions – OPEN, OFF, CLOSE.

Related Articles

A display of professional architectural brochures and floor plans arranged on a teal surface. The brochures detail various building designs, showcasing photographs, technical diagrams, and innovative features such as natural ventilation systems.

Downloads

Product datasheets, installation instructions or drawings

A person reviews architectural blueprints on a computer screen, focusing on detailed floor plans.

Blog

Advice, inspiration and industry news

Related Products

WindowMaster

WSC 310-PLUS – AOV Control Unit

WindowMaster CompactSmoke WSC 310-PLUS Smoke Control AOV Panel 2 zone, 10 Amp for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation.

Motor Load

10 amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

2

VCS-S2 – AOV Control Unit [Discontinued]

VCS-S2 Smoke Control AOV Panel (5.0 Amp) for the operation of 24VDC AOV or OV’s. Complete with Fire Alarm interface and 72 hour battery backup system as standard.

Motor Load

5 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1
WindowMaster

WSC 204 – AOV Control Unit [Discontinued]

Windowmaster WSC 204 Smoke Control AOV Panel (4.8 Amp) for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation.

Motor Load

4.8 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1
WindowMaster

WSC 520 – AOV Control Unit

WindowMaster WSC 520 Smoke Control AOV Panel for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation. Can be configured to operate up to 13 motorlines, with a 20 Amp max. motor load.

Motor Load

20 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1 5 9 13
WindowMaster

WSC 104 – AOV Control Unit

WindowMaster WSC 104 smoke control AOV panel (4 Amp) for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation.

Motor Load

4 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1
Teal Products

SCP500 – AOV Control Unit

SCP500 AOV Control Panel (5 Amp) for the operation of 24V DC AOV or OV’s. Complete with Fire Alarm interface and 72 hour battery backup system as standard.

Motor Load

5 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1
Teal Products

SCP800 – AOV Control Unit

SCP800 AOV Control Panel (8 Amp) for the operation of 24V DC AOV or OV’s. Complete with Fire Alarm interface and 72 hour battery backup system as standard.

Motor Load

8 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1