Inputs & Accessories

Teal Products are the UK’s leading stockist of accessories and spare parts for Smoke Ventilation Systems. We carry large stocks in our Gloucestershire warehouse from a wide range of manufacturers and compatible with many system types – all stocked items can be with you as fast as next day delivery! If you’re installing a new system or responsible for maintaining building life safety systems and minimising system down time and need a part urgently – call our friendly team now.

Products

HMI smoke vent system status display and control interface
Teal Products

HMI-KNX – Smoke Vent System Interface

HMI-KNX touchscreen interface for use as part of a smoke ventilation control system. The user is able to drill down zone by zone to view the current system status. Customise – The system is fully customisable, allowing the user to input zone names, project name and contact information for service and support.

HMI smoke vent system status display and control interface
Teal Products

HMI-SCP – Smoke Vent System Interface

HMI-SCP touchscreen interface for use as part of a smoke ventilation control system. The user is able to drill down zone by zone to view the current system status as well as give a manual open or close/reset command per zone.

WSC MP mimic indicator panel for a smoke ventilation system.
Teal Products

WSC MP – Mimic Panel

WSC MP mimic panel with LED indicators for use as part of a smoke ventilation system. Pre-configured to respond to 12 group objects (1-12) from WindowMaster FlexiSmoke control panel with KNX field bus module.

A yellow smoke vent control switch with a white panel and black directional arrow symbols, designed to manually activate smoke ventilation in emergencies.

BG1/S – Breakglass Callpoint

BG1/S Manual Call Point (Breakglass) for use with our range of Smoke Vent Panels. Upon a signal from the BG1/S Call Point the Smoke Vent Control Panel will send an open signal to the Automatic Smoke Vent.

A yellow smoke vent control box with an open/close switch, perfect for integrating into door automation or window actuators systems.

BG1/FOS – Firemans Switch

BG1/FOS Manual Call Point (Switch) for use with our range of Smoke Ventilation Control Panels. Smoke Call Point will allow for an open or close signal to be sent to AOV Smoke Vent upon the detection of Smoke.

Orange smoke vent control panel with two buttons labeled "Open" and "Close/Reset.
Teal Products

BG3-PRO – Manual Call Point

Designed for use with our own SCP Control Unit. This Manual Call Point uses only a 3-core cable and features a built-in temperature sensor with LED indication. It allows direct connection of smoke sensors and/or comfort switches for flexible control of AOV Smoke Vents.

An orange smoke vent control box with a red button and a label indicating "SMOKE VENT" ensures efficient smoke ventilation in emergency situations.
Teal Products

BG3/FOS – Manual Call Point

BG3/FOS Manual Call Point (Switch) for use with our range of Smoke Ventilation Control Panels. Smoke Call Point will allow for an open or close signal to be sent to AOV Smoke Vent upon the detection of Smoke.

A square yellow box labeled "Smoke Vent" features a central key slot flanked by two arrow buttons, seamlessly integrating with window actuators for enhanced natural ventilation.
Teal Products

BG4/FOS – Firemans Key Switch

BG4/FOS Firemans Key Switch for use with our range of Smoke Ventilation Control Panels. Smoke Call Point will allow for an open or close signal (via Control Panel) to be sent to AOV Smoke Vent upon the detection of Smoke.

A double electrical panel with labeled switches and dials, featuring warning signs and a light gray exterior.

ATS1 – Automatic Transfer Switch

The ATS1 unit is a budget mains to generator model and includes a warm up and cool down timer as well as a volt free start contact on mains failure to signal the GenSet to start the generator. They do not rely on a DC power supply to operate so will function equally well as a mains to mains system.

A gray industrial pressure switch with a transparent cover is mounted on a rectangular metal box.

DPS24 – Differential Pressure Switch

The DPS24 Differential Pressure Switch monitors building pressure levels and interfaces with the FCP1000 control unit. If pressure is too high during fan operation, the DPS24 signals the FCP1000 to reduce fan speed, ensuring safe and efficient smoke extraction.

Orange smoke vent control panel with a key switch and labels for "Auto" and "Boost.
Teal Products

BG7/FOS – Firemans Key Switch

BG7/FOS manual key switch for manual operation of smoke extract fan. Compatible with FCP1000 fan control panel. Supplied with protective cover and back box for surface mounting.

A square yellow box labeled "Smoke Vent" features a central key slot flanked by two arrow buttons, seamlessly integrating with window actuators for enhanced natural ventilation.
Teal Products

BG6/FOS – Firemans Key Switch

BG6/FOS Firemans Key Switch for use with our range of Smoke Ventilation Control Panels. Smoke Call Point will allow for an open or close signal (via Control Panel) to be sent to AOV Smoke Vent upon the detection of Smoke.

A yellow smoke vent emergency button mounted on a white wall, used to release smoke from a building in case of fire and assist with natural ventilation.
WindowMaster

WSK 501 – Manual Call Point

WindowMaster WSK 501 manual call point (Breakglass) for use with compatible Smoke Control Panels. Upon a signal from the Manual Call Point (MCP) the AOV or OV Smoke Vent will open releasing the smoke detected in that area.

A yellow smoke vent emergency button mounted on a white wall, used to release smoke from a building in case of fire and assist with natural ventilation.
WindowMaster

WSK 503 – Manual Call Point

Windowmaster WSK 503 manual call point (break glass) for use with compatible smoke control panels. Upon a signal from the manual call point (MCP) the AOV or OV smoke vent will open releasing the smoke detected in that area.

A white, circular smoke detector mounted on a white background.

SSR3 Optical Smoke Sensor & Standard Base

The SSR3 Optical Smoke Sensor is designed for use with our range of smoke control AOV panels. When triggered by the SSR-D smoke sensor, the AOV Control Panel sends an open signal to the AOV Actuator.

 

White smoke detector with circular design, featuring a central button and vent-like openings around the perimeter for optimal smoke ventilation, mounted on a white background.

SSR – Smoke Sensor

SSR optical Smoke Sensor for use with our range of smoke control AOV panels. Upon a signal from the SSR-D smoke sensor the AOV Control Panel will send an open signal to the AOV Actuator.

Frequently asked questions:

What are the most common smoke ventilation spares used in AOV systems?

The most common service components that need replacing in Smoke Ventilation Systems are smoke panel batteries, frangible elements and glass for break glass units, manual callpoints, smoke detectors and AOV Smoke Vent Control Panels. For emergency repairs we also receive alot of calls about actuators and for wider system refurbishment we provide a wide range of certified AOVs (Automatic Opening Vents)and smoke control dampers.

How do I identify if my smoke ventilation system needs replacement parts?

Smoke Ventilation Systems should be subject to regular testing and maintenance, as well as routine risk assessments to ensure the system still operates as intended and meets the latest design guidance, regulations and performance requirements. Often these tests and inspections will reveal components that are at risk of failure or improper operation as a result of tampering, damage, end of life or updates to operational requirements that mean they no longer perform as required.

What is the difference between different smoke vent control panels and smoke ventilation accessories?

Different manufacturers use different approaches to designing and building their system functionality and communication between devices. As a result different manufacturers often have different requirements for the field cabling and accessories attached to their smoke ventilation panels. Teal’s experts can help find like for like replacement or backward compatible components and panels that meet the latest standards.

Are smoke ventilation spares compatible across different brands and models?

Many manufacturers standardise on certain accessories and components which may be branded differently, or use similar protocol and are interchangeable and compatible with each other – however, careful consideration needs to be given to the method of wiring, connections and interchangeability to maintain certification, compliance and ensure the system (and building occupants) are not put at risk. Teal can help source like for like or interchangeable items that are fully backward compatible.

Can you recommend trusted suppliers for smoke ventilation system spares in the UK?

While there are a number of suppliers of smoke ventilation spare parts in the UK, few have the range of manufacturers, stock and expertise that Teal Products offer. For the best levels of support, product availability and pricing – as well as next day deliveries, Teal Products are hard to beat – get it right first time, on time, with Teal Products.

How do I choose the right replacement part for my smoke ventilation system?

We recommend taking details of the part number along with manufacturer name, model number and photograph of the outside (and if already accessible by competent persons the connections inside) the item that needs replacing. These can be emailed to info@tealproducts.co.uk who will review the parts needed and advise on best prices and availability – normally with same day turn around on enquiries. For more urgent smoke ventilation spares please call 01242 620318 for more immediate guidance.

Often it can also help to take details of the AOV Control System Panel to ensure compatibility.

What maintenance tips can help extend the life of smoke ventilation accessories?

Regular testing and maintenance, as well as planned replacement of parts like batteries can help ensure vital component effectiveness and longevity, helping to identify any potential issues that can be addressed

What are the essential accessories needed for maintaining a smoke ventilation system?

Critical components include smoke detectors, callpoints, breakglasses and other system accessories that help integrate between the fire alarm systems, smoke ventilation controls and AOV windows and AOV rooflights. Other common replacement parts are rocker switches for comfort ventilation and manual override of natural smoke ventilation vents and pressures switches in mechanical systems for mechanical smoke ventilation of larger buildings.

Where can I buy Velux smoke control spare parts online?

Teal Products carry a broad range of spare parts and accessories compatible with Velux smoke vents – please contact us to discuss your exact requirements and we’d be happy to advise what we have available or alternative sources or solutions.

Where can I buy urgent smoke vent system spares in the UK?

Teal Products are one of the UK’s largest providers of urgent smoke ventilation spares and accessories for new system installations and system maintenance – carrying a wide range of stock from different manufacturers at great prices and quick deliveries. For expert guidance and help with accessories or urgent spare parts for smoke ventilation systems call Teal Products on 01242 620318 or email info@tealproducts.co.uk