SCP500 – AOV Control Unit
SCP500 AOV Control Panel (5 Amp) for the operation of 24V DC AOV or OV’s. Complete with Fire Alarm interface and 72 hour battery backup system as standard.
BG6/FOS Firemans Key Switch for use with our range of Smoke Ventilation Control Panels. Smoke Call Point will allow for an open or close signal (via Control Panel) to be sent to AOV Smoke Vent upon the detection of Smoke.
In stock, next day delivery
SCP500 AOV Control Panel (5 Amp) for the operation of 24V DC AOV or OV’s. Complete with Fire Alarm interface and 72 hour battery backup system as standard.
SCP800 AOV Control Panel (8 Amp) for the operation of 24V DC AOV or OV’s. Complete with Fire Alarm interface and 72 hour battery backup system as standard.
WindowMaster CompactSmoke WSC 310-PLUS Smoke Control AOV Panel 2 zone, 10 Amp for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation.
WindowMaster WSC 520 Smoke Control AOV Panel for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation. Can be configured to operate up to 13 motorlines, with a 20 Amp max. motor load.
WindowMaster FlexiSmoke WSC 540 Smoke Control AOV Panel for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation. Can be configured to operate up to 26 motorlines, with a 40 Amp max. motor load.
WindowMaster FlexiSmoke WSC 560 Smoke Control AOV Panel for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation. Can be configured to operate up to 39 motorlines, with a 60 Amp max. motor load.
Thank you so much to those who made to trip to the Fire Safety Event (FSE) this week. It meant a lot to us to finally be able to share and demonstrate some of our newest products. Your feedback on the new HMI-SCP touchscreen and BG3 call point has been fantastic!
There are many types of ventilation, many of which are categorised as a form of smoke ventilation or natural ventilation. Providing buildings with ventilation controls is essential for complying with Approved Document B – Fire Safety, or Approved Document F – Ventilation of the UK Building Regulations.
Generally, electric window openers, also known as electric window actuators, are operated remotely.
SCP500 AOV Control Panel (5 Amp) for the operation of 24V DC AOV or OV’s. Complete with Fire Alarm interface and 72 hour battery backup system as standard.
Motor Load
Voltage Input
Voltage Output
Zones
SCP800 AOV Control Panel (8 Amp) for the operation of 24V DC AOV or OV’s. Complete with Fire Alarm interface and 72 hour battery backup system as standard.
Motor Load
Voltage Input
Voltage Output
Zones
BG3/FOS Manual Call Point (Switch) for use with our range of Smoke Ventilation Control Panels. Smoke Call Point will allow for an open or close signal to be sent to AOV Smoke Vent upon the detection of Smoke.
Windowmaster WSK 320 Manual Call Point (Breakglass) for use with WSC204/KP Smoke Control Panels. Upon a signal from the Manual Call Point (MCP) the AOV or OV Smoke Vent will open releasing the smoke detected in that area.