A closed, wall-mounted metal electrical panel box with a keyhole, a small label on the top right, and a large yellow warning label towards the bottom on a plain white background, commonly used in smoke ventilation systems.
Diagram showing a fire alarm system layout with components labeled: WLA 330 Wind & Rain Sensor, SSR-D Smoke Sensor, AOV c/w 24V DC Actuator for smoke ventilation, WSC 204 Control Unit, WSK 320 Manual Callpoint, and WLA 331 Rain Sensor.

WSC 204 – AOV Control Unit [Discontinued]

Logo of WindowMaster

Description

Windowmaster WSC 204 Smoke Control AOV Panel (4.8 Amp) for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation.

Get a quote

In stock, next day delivery

Additional details

  • Control for 24V DC Window Actuators (4.8 Amp max)
  • 1-Zone
  • Input options for Manual Callpoints
  • Smoke Sensor, Fire Alarm (using WSA306)
  • Rocker Switch, Wind & Rain Sensors
  • Supplied with batteries
  • Certified and tested in accordance to EN 12101-10
  • Motor Lines 1

Motor Load

4.8 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1

WSK 320 – Manual Call Point [Discontinued]

Windowmaster WSK 320 Manual Call Point (Breakglass) for use with WSC204/KP Smoke Control Panels. Upon a signal from the Manual Call Point (MCP) the AOV or OV Smoke Vent will open releasing the smoke detected in that area.

SSR-D – Smoke Sensor

SSR-D optical Smoke Sensor for use with our range of smoke control AOV panels. Upon a signal from the SSR-D smoke sensor the AOV Control Panel will send an open signal to the AOV Actuator.

Related Articles

A display of professional architectural brochures and floor plans arranged on a teal surface. The brochures detail various building designs, showcasing photographs, technical diagrams, and innovative features such as natural ventilation systems.

Downloads

Product datasheets, installation instructions or drawings

A person reviews architectural blueprints on a computer screen, focusing on detailed floor plans.

Blog

Advice, inspiration and industry news

Related Products

WindowMaster

WSC 310-PLUS – AOV Control Unit

WindowMaster CompactSmoke WSC 310-PLUS Smoke Control AOV Panel 2 zone, 10 Amp for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation.

Motor Load

10 amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

2

VCS-S2 – AOV Control Unit [Discontinued]

VCS-S2 Smoke Control AOV Panel (5.0 Amp) for the operation of 24VDC AOV or OV’s. Complete with Fire Alarm interface and 72 hour battery backup system as standard.

Motor Load

5 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1
WindowMaster

WSC 204 – AOV Control Unit [Discontinued]

Windowmaster WSC 204 Smoke Control AOV Panel (4.8 Amp) for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation.

Motor Load

4.8 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1
WindowMaster

WSC 520 – AOV Control Unit

WindowMaster WSC 520 Smoke Control AOV Panel for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation. Can be configured to operate up to 13 motorlines, with a 20 Amp max. motor load.

Motor Load

20 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1 5 9 13
WindowMaster

WSC 104 – AOV Control Unit

WindowMaster WSC 104 smoke control AOV panel (4 Amp) for control of ±24V DC Actuators for the function of smoke extraction combined with daily comfort ventilation.

Motor Load

4 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1
Teal Products

SCP500 – AOV Control Unit

SCP500 AOV Control Panel (5 Amp) for the operation of 24V DC AOV or OV’s. Complete with Fire Alarm interface and 72 hour battery backup system as standard.

Motor Load

5 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1
Teal Products

SCP800 – AOV Control Unit

SCP800 AOV Control Panel (8 Amp) for the operation of 24V DC AOV or OV’s. Complete with Fire Alarm interface and 72 hour battery backup system as standard.

Motor Load

8 Amp

Voltage Input

230V AC

Voltage Output

24V DC

Zones

1